MCM Replacement:
MCM13 2743->3047
elog
| 83 | + | 86 | CERN | 2014-07-07 | MCM replacement:
Replaced MCM 2722 (position 8) with MCM 2789 due to ambiguous DB entries. The PPM was retested (single board tests).
Victor Andrei | Update Tests KS |
|
84 | + | 84 | CERN | 2014-07-07 | MCM replacement:
The MCM 2756 (position 10) was replaced with the MCM 2790 due to ambiguous DB entries.
Victor Andrei | The PPM was successfully retested with the new MCM.
Victor Andrei | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
85 | + | 87 | CERN | 2018-03-26 | Hardware:
replaced MCM 2 SerNr 4533 -> 3247
No Serial Interface
replaced MCM 13 SerNr 4551 -> 3245
Analog Ch2 Bad ADC values
CAN R4k7 implemented | Update Tests KS | simulation errors |
|
86 | + | 89 | CERN | 2014-08-31 | This PPM is at CERN (Cr.1, Slot10) acc. to RA's listing on Okt.07 ? ? ? | Location of the module:
The module is in Heidelberg and it needs to be retested after it failed initial LVDS tests. The module which is believed to be at CERN (as actually planned) is PPM# 99 (see the comments for this module).
Victor Andrei | LVDS Tests (Full Crate):
Klaus has replaced MCM#8 (initially serNr 4327, now serNr 2955) due to bad values provided by the 'temperature' diode. The problem occured after the module has passed the Single Board Tests (see the temperature map created during the Full Crate Tests for PPM# 122 and compare it with the similar map for PPM# 100; see also the date when the tests were done). Also, Klaus has replaced MCM#5 (initially serNr 4317, now serNr 2956) due to missing externalBCID bit (initially not detected during the Single Board Tests).
Victor Andrei | The externalBCID bit is missing from the ROD buffer (it's not set though it should be).
Victor Andrei
|
|
87 | + | 90 | CERN | 2014-08-31 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
88 | + | 91 | CERN | 2009-09-18 | Hardware:
Replaced the following MCMs:
* MCM SerNr 4339 (slot# 3) with MCM SerNr 3135 due to LVDS clock problems;
* MCM SerNr 4342 (slot# 5) with MCM SerNr 3129 due to ASIC playback errors;
* MCM SerNr 4347 (slot# 9) with MCM SerNr 3130 due to bad JEP-LVDS data;
* MCM SerNr 4348 with MCM SerNr 3132 (bit# 7 permanently missing in the JEP-LVDS output).
VA & KS | Hardware (Ananlogue problems):
Replaced the following MCMs due to bad FADC output:
* MCM SerNr 4338 (slot# 2) with MCM SerNr 3133 --> errors observed on digChan# 2;
* MCM SerNr 4341 (slot# 4) with MCM SerNr 3131 --> errors observed on digChan# 4;
* MCM SerNr 4351 (slot# 12) with MCM SerNr 3136 --> errors observed on digChan# 2;
* MCM SerNr 4353 (slot# 14) with MCM SerNr 3138 --> errors observed on digChan# 4;
VA & KS | LVDS Tests (Full Crate):
Could not upload the latest debug file, because the file is too big. Therefore, the current debug file available in the database describes previous tests. The new file must be uploaded by hand.
Victor Andrei
| MCM0 set to Zero must by checked
KS |
|
89 | + | 92 | CERN | 2018-10-11 | LVDS Tests (Full Crate) :
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | Hardware (LVDS errors):
Replaced the following MCMs:
* MCM SerNr 4359 (slot #2) with MCM SerNr 3139 due to LVDS-JEP errors (bit#8 permanently missing);
* MCM SerNr 4369 (slot #10) with MCM SerNr 3140 due to LVDS-JEP errors (bit#4 permanently missing).
VA & KS
| Hardware (Analogue errors):
Replaced the following MCMs:
* MCM SerNr 4361 (slot #3) with MCM SerNr 3141 due bad FADC data on digChan# 4;
* MCM SerNr 4363 (slot #5) with MCM SerNr 3142 due to bad FADC data on digChan# 3 and 4;
* MCM SerNr 4376 (slot #14) with MCM SerNr 3143 due bad FADC data on digChan# 1 aand 3;
* MCM SerNr 4378 (slot #16) with MCM SerNr 3144 due to bad FADC data on digChan# 3.
VA & KS | Hardware:
Replaced MCM SerNr 4377 (slot# 15) with MCM SerNr 3154 due to large FADC data width seen on the AnCh# 4.
The change was actually done on 20.06.2008, and the PPM was retested in the new configuration (only on the light crate setup)
VA & KS | PPM was in KIP for Repair. All MCMs except 12-14&16 exchanged. The new population as of April 29. 2010 | Replaced nMCM 11071 by 10392 on 18.05.18 |
|
90 | + | 93 | CERN | 2014-05-08 | Hardware
The following MCMs were replaced due to bad ADC data:
* MCM SerNr 4379 (slot# 1) with MCM SerNr 3175;
* MCM SerNr 4380 (slot# 2) with MCM SerNr 3176;
* MCM SerNr 4384 (slot# 5) with MCM SerNr 3177;
* MCM SerNr 4389 (slot# 8) with MCM SerNr 3178.
Victor Andrei | Hardware:
Replaced MCM 2800 (slot# 13) with MCM SerNr 3173 due to a relatively high error rate of PHOS4 initialization.
Victor Andrei | Hardware:
CAN R4k7 implemented.
KS | Problem: Do not know MCM Nr. 3
Update Tests KS |
|
91 | + | 94 | CERN | 2014-08-31 | |
92 | + | 95 | CERN 104 | 2019-12-12 | Hardware:
Replaced the following 5 MCMs:
* MCM SerNr 4429 (slot# 4) with MCM SerNr 3123 --> errors: broken ASIC diode (temp mesurement) and bad FADC data (digChan# 3)
* MCM SerNr 4428 (slot# 5) with MCM SerNr 3124 --> errors: bit# 4 & 8 permanently missing in the JEP-LVDS, and bad FADC data (digChan# 2)
* MCM SerNr 4434 (slot# 8) with MCM SerNr 3125 --> errors: bad FADC data (digChan# 3)
* MCM SerNr 4440 (slot# 11) with MCM SerNr 3126 --> errors: bad FADC data (digChan# 4)
* MCM SerNr 4443 (slot# 14) with MCM SerNr 3127 --> errors: PHOS4 initialization error.
Va & KS | Taken out from P1 (it was in PP0 PPM15) because bad channel 01f0801, first spiky then died. Problem probably due to AnIn3 (179).
Now in testrig, last slot | Update database for module replacements in 2018 | Back in HD for repair.
Removed working CAN board # 95 and installe in PPM 121, now under power in testrig 104, last slot | AnIn board # 3 (179, causing problems in data taking in 2018) replaced by (#229).
PPM back to CERN, b104 TR, slot 5, equiped with TREX_v2 | CAN board with new FW was also installed on it |
|
93 | + | 96 | CERN | 2014-07-03 | JEP LVDS output errors: Errors observed at CERN, module brought back to Heidelberg for more investigations.
Victor & Klaus
| LVDS Tests:
Bits missing in the LVDS-JEP output of the MCM#1 (bitNr 6/10) and MCM#2 (bitNr 7/10). Replaced MCM#1 (previously serNr 4449, currently serNr 3084) and MCM#2 (previously 4450, currently 3085) and redid the analogue and the digtal tests with the new MCMs.
Victor & Klaus. | Hardware:
Replaced MCM# 6 (SerNr 4458), MCM# 14 (SerNr 4469) and MCM# 16 (SerNr 4472) with the MCMs SerNr 3099, 3109 and 3110 due to bad FADC data.
Victor Andrei | Test Results:
The module was completly retested with the new MCMs. No error was observed.
Victor Andrei | Hardware:
Replaced MCM SerNr 4467 (slot#12) with MCM SerNr 3181 due to bad JEP-LVDS data (bit#5 missing). Also, replaced MCM SerNr 4468 (slot#13) with MCM SerNr 3180 due to bad ASIC readout data.
Victor Andrei
| Hardware:
CAN R4k7 implemented. | Update Tests KS | Replaced nMCM #10313 in Slot 10 |
|
94 | + | 97 | CERN | 2017-07-04 | Hardware:
Replaced MCM SerNr 4477 (MCM slot# 3) with MCM SerNr 3115 due to bad data format on the the ASIC serial interface. Also, replaced MCM SerNr 4480 (MCM slot# 6) with MCM SerNr 3116 (no data on both serial interfaces).
Victor & Klaus | Hardware:
Replaced MCM SerNr 4473 (MCM slot# 1) with MCM SerNr 3117 due to bad FADC data (digChan# 0) and LVDS lock missing (CP, chan# 1). Also, replaced MCM SerNr 4476 (MCM slot# 2) with MCM SerNr 3118 (bit#9 - the 2nd MSB - permanently missing in the JEP LVDS output).
Victor & Klaus | Hardware (LVDS errors, Full Crate Test):
Replaced MCM SerNr 4478 (slot# 4) with MCM SerNr 3155 due to bad LVDS data on digChan# 3 (affects both CP and JEP output).
Victor Andrei. | Hardware:
Replaced MCM SerNr 4492 (slot# 14) with MCM SerNr 3153 due to bad FADC voltage window observed for the AnCh# 1.
The change was actually done on 20.06.2008, and the PPM was retested in the new configuration (only on the light crate setup).
VA & KS | Replace 12189 with 12252 |
|
95 | + | 98 | CERN | 2014-07-07 | Hardware:
replaced MCM 2 SerNr 4516 -> 3163
Bad ADC Data
replaced MCM 6 SerNr 4520 -> 3170
No Serial Interface both
replaced MCM 9 SerNr 4524 -> 3164
Bad ADC Data
replaced MCM 11 SerNr 4526 -> 3169
No Serial Interface both
CAN R4k7 implemented
| PPM #98 was in KIP for Repair
PPM #98: All MCMs exchanged. The new population as of April 29. 2010: | Update Tests KS |
|
96 | + | 99 | CERN | 2018-07-24 | Location Ambiguity:
Check if the module was really sent to CERN!
Victor Andrei | PPM was in KIP for Repair. MCM09, MCM14 & MC16 exchanged. | The PPM is actually in HD not at CERN | from HD to CERN 104, spare board | down in USA15 and plugged in PP2 slot 0 as spare, after having replaced PP0PPM15 for broken AnIn |
|
97 | + | 108 | CERN | 2018-10-11 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | nMCM 11955 replaced by 11251 on 18.09.18 |
|
98 | + | 105 | CERN | 2014-08-31 | MCM replacement
MCM02: 3420<->3067
elog link
Pavel |
|
99 | + | 103 | CERN, PP6 | 2021-05-10 | PPM was in KIP for Repair. All MCMs exchanged. The new population as of April 30th 2010 | CAN 81 needs R3 resistor in order to flush CAN FW | Currently unplugged in TestRig because without CAN board | CAN board back after repair, seems to be working now | Updating database for module replacements in 2018 | Installed in P1, PP6 during TREX installation, on PP6PPM0 replacing PPM #100, found to be with power up problems |
|
100 | + | 127 | CERN | 2014-07-03 | |
101 | + | 128 | CERN | 2014-08-31 | LVDS Tests (Full Crate): The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
102 | + | 101 | CERN | 2014-07-03 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
103 | + | 102 | CERN | 2014-08-31 | |
104 | + | 107 | CERN | 2014-08-31 | LVDS Tests (Full Crate): The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | LVDS Tests (Full Crate):
The high temperature value recorded on the MCM in slot#13 was due to an unsoldered pin of the Multiplexer chip. The problem is fixed now and the temperature values are as expected.
Victor Andrei | MCM2 replaced
4609<->3076 elog link
PW |
|
105 | + | 110 | CERN | 2014-08-31 | |
106 | + | 111 | CERN | 2014-08-31 | |
107 | + | 112 | CERN | 2014-08-31 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
108 | + | 114 | CERN | 2014-08-31 | |
109 | + | 115 | CERN | 2014-08-31 | |
110 | + | 118 | CERN | 2014-07-03 | |
111 | + | 117 | CERN | 2014-08-28 | MCM4 Replaced: Was 4654, now it's 4618 |
|
112 | + | 119 | CERN | 2014-07-03 | |
113 | + | 120 | CERN | 2014-07-03 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, and therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
114 | + | 125 | CERN | 2014-08-31 | MCM 3714<->3071 in MCM9
elog link
Pavel Weber |
|
115 | + | 104 | CERN | 2014-07-03 | |
116 | + | 122 | CERN | 2014-08-31 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
117 | + | 123 | CERN | 2014-08-31 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
118 | + | 130 | CERN TestRig | 2018-10-11 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | Hardware:
The module was brought back to Heidelberg for investigations. We could not reproduce the error reported from CERN and, also, we did not find any other problem (during Single Board Tests).
Victor Andrei | b>Hardware:
replaced MCM 8 SerNr 3881 -> 3202
Bad Temp. Diode
replaced MCM 12 SerNr 3887 -> 3145
sometimes ADC Data Problems
CAN R4k7 implemented
KS | PPM was in KIP for Repair. MCM01, MCM06, MCM09 and MCM11 exchanged.
CAN-Brd changed to #179. The new population as of
April 30th 2010 | Update Tests KS | Replaces PPM 51 in Test Reg Slot 12 | swpped can 179 with 103 | CAN (103) power cycles the board after ~ 5min and then switches the PPM completely OFF after other ~ 5min | Problem solved with new CAN FW 5.8.1 | Correctly marked as being in TestRig |
|
119 | + | 131 | CERN | 2014-08-31 | |
120 | + | 132 | CERN | 2014-08-31 | Hardware:
Replaced MCM SerNr 2958 (MCM slot# 1) with MCM SerNr 3119 (only in BcMux mode, bit# 5 - bit# 3 of the LUT value - is missing for chan# 1, LVDS to CP output). Also, replaced MCM SerNr 3845 (MCM slot# 13) with MCM SerNr 3120 (found bit#5 of the LVDS to JEP output missing permanently).
va & ks
| Hardware:
Replaced MCM SerNr 3836 (slot#5) with MCM SerNr 3122 due to bad FADC data observed during SPI-DAC scans.
va & ks |
|
121 | + | 135 | CERN | 2014-08-31 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
122 | + | 134 | CERN | 2010-10-19 | Hardware:
replaced MCM 2 SerNr 3894 -> 3187
JEP LVDS Errors
replaced MCM 4 SerNr 3897 -> 3182
phos4 init error
CAN R4k7 implemented. | Update Tests KS |
|
123 | + | 137 | CERN | 2014-08-31 | MCM 3921 in MCM8 replaced
3921<->3070
elog link
Pavel Weber |
|
124 | + | 138 | CERN | 2017-09-19 | nMCM replacement: https://atlasop.cern.ch/elisa/display/318286 | Fixing a previous mistake: It was nMCM 11571 and not 11579 which was exchanged. See: https://atlasop.cern.ch/elisa/display/333335
| Remove nMCM 10389 which was apparently entered here by mistake. | nMCM #11567 was replaced by #11653 due to timing problems: https://atlasop.cern.ch/elisa/display/308255 |
|
125 | + | 139 | CERN | 2014-07-07 | Hardware:
replaced MCM 4 SerNr 3951 -> 3151
AnCh3 Bad ADC Data width
| Update Tests KS | Update Tests KS |
|
126 | + | 140 | CERN | 2014-08-31 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
127 | + | 141 | CERN TestRig | 2018-10-11 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | PPM was in KIP for Repair. CAN-Brd changed to #42. All MCMs beside MCM09 exchanged. The new population as of April 30th 2010 | Correctly marked as being in TestRig |
|
128 | + | 67 | CERN | 2014-07-07 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | Hardware (Analogue problem):
Replaced MCM SerNr 2384 (slot# 12) with MCM SerNr 3162 due to bad FADC data.
Va & KS |
|
129 | + | 68 | CERN | 2014-05-08 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
130 | + | 69 | CERN | 2014-07-07 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | Hardware (Analogue problem):
Replaced MCM SerNr 2306 (slot# 11) with MCM SerNr 3146 due to bad FADC data on digChan# 1.
VA & KS
|
|
131 | + | 70 | CERN | 2014-05-09 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
132 | + | 71 | CERN | 2014-05-09 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
133 | + | 72 | CERN | 2014-05-09 | |
134 | + | 73 | CERN | 2014-05-09 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
135 | + | 74 | CERN | 2014-05-09 | |
136 | + | 106 | CERN | 2014-08-31 | |
137 | + | 124 | CERN | 2014-08-31 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
138 | + | 142 | CERN | 2017-09-19 | Two nMCM replaced due to problems.
https://atlasop.cern.ch/elisa/display/356943
|
|
139 | + | 126 | CERN | 2014-07-04 | Firmware
SPI-DAC problems with the old f/w. The module is currently used as test board for the new f/w.
KS & VA
| LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | MCM Replacement:
All MCMs previously mounted on PPM 126 were removed and brought to CERN to serve as 'MCM spares'. They were replaced on the board with the following MCMs (only SerNr given):
MCM_SlotNr Prev_MCM Current_MCM
# 1 3060 4707
# 2 3061 4708
# 3 3063 4709
# 4 3065 4710
# 5 3066 4711
# 6 3067 4712
# 7 3068 4713
# 8 3069 4714
# 9 3070 4715
# 10 3071 4716
# 11 3072 4717
# 12 3073 4718
# 13 3074 4719
# 14 3075 4720
# 15 3076 4721
# 16 3077 4722
The module will be completely retested with the new MCMs.
Victor Andrei. | MCM changed KS
#2 4708 1225
#11 4717 3112
|
|
140 | + | 136 | CERN | 2018-07-24 | Readback:
Found LUT readback errors for MCM# 2 (SerNr 1227), chan# 3 (2nd serIntf, first channel). Replaced the MCM with MCM SerNr 3111.
Victor Andrei | Hardware:
do not found MCM2 SerNr 3111 ???
found MCM2 SerNr 3171
CAN R4k7 implemented
KS | Update Tests KS | used PPM, before plugged in PP2 as spare board, as PP0PP15, snce the prevous one had a bad AnIn. Problem fixed |
|
141 | + | 144 | CERN | 2014-08-31 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
142 | + | 146 | CERN | 2014-05-08 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
143 | + | 147 | CERN | 2014-05-09 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | Hardware:
Found possible asymmetric LVDS output for MCM# 9, ch# 1. Replaced the MCM (SerNr 4027) with another MCM (SerNr 3100) and redid all tests with the new MCM.
Victor Andrei
| The MCM 3061 added to the database according to the MCM list from Taylor |
|
144 | + | 148 | CERN | 2014-07-03 | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei |
|
145 | + | 149 | CERN | 2014-08-31 | |
146 | + | 150 | CERN | 2014-08-31 | Hardware:
Found possible asymmetric LVDS output for MCM# 15, ch# 2. Replaced the MCM (SerNr 4094) with another MCM (SerNr 3102) and redid all tests with the new MCM.
Victor Andrei |
|
147 | + | 151 | CERN | 2014-08-31 | |
148 | + | 152 | CERN | 2014-08-31 | Hardware:
Found possible asymmetric LVDS output for MCM# 6, ch# 1. Replaced the MCM (SerNr 4102) with another MCM (SerNr 3103) and redid all tests with the new MCM.
Victor Andrei |
|
149 | + | 153 | CERN | 2014-08-31 | |
150 | + | 155 | CERN | 2014-08-31 | Hardware:
Found possible asymmetric LVDS output for MCM# 16, ch# 3. Replaced the MCM (SerNr 4175) with MCM SerNr 3104. Also, replaced MCM# 9 (SerNr 4167) and MCM# 10 (SerNr 4169) with MCM SerNr 3105 and MCM SerNr 3107 due to bad FADC data (digCh# 4 on both MCMs). Redid all tests with the new MCMs.
Victor Andrei | LVDS Tests (Full Crate):
The debug file is not uploaded. The module was tested over night, therefore the size of the debug file is much larger than the currently allowed size for uploading files into DB.
Victor Andrei | Replaced MCM 4166 with MCM 3075 in MCM8
elog link
Pavel Weber |
|
151 | + | 154 | CERN 104 | 2019-12-12 | Hardware:
Replaced MCM SerNr 4138 (slot# 4) with MCM SerNr 3179 due to bad JEP-LVDS data .
Victor Andrei | Hardware:
CAN R4k7 implemented. | PPM was in KIP for Repair. All MCMs beside MCM16 exchanged. The new population as of April 29. 2010 | Remove + | Remove + | V6 error reported on the front-panel display. nMCM numbers obsolete (point to old MCMs). | V6 error understood (it was induced by a wrongly placed GND probe). But the board shows issues on +3.3V on power-up and when more than 6 nMCM are mounted, which affects the operation of some power regulators on the TREX (i.e. ATX_1V0 and KTX_0V95 have 0V output). | apparently the power problem was only due to CAN old FW. Solved updating new CAN FW.
PPM now installed at CERN n TR 104, slot #7 with TREX (not cabledwith LVDs) |
|
152 | + | 156 | CERN | 2014-07-03 | test | Changed MCM after 6Weeks burnin
MCM 04 4179->3233 ADC-Bit Err
MCM 09 4185->3194 ADC-Bit Err
MCM 10 4186->3241 ADC-Bit width | Changed MCM 4178->4750
Bad LVDS Data JP |
|
153 | + | 157 | CERN | 2014-08-31 | Changed MCM after 6Weeks burnin MCM 04 4203->3188 ADC4-Bit Err
MCM 05 4204->3189 ADC3-Bit Err
MCM 09 4211->3218 ADC-Bit width
MCM 10 4209->3190 ADC-Bit width | Changed MCM after 6Weeks burnin MCM 04 4203->3188 ADC4-Bit Err
MCM 05 4204->3189 ADC3-Bit Err
MCM 09 4211->3218 ADC-Bit width
MCM 10 4209->3190 ADC-Bit width | Changed MCM after 6Weeks burnin MCM 04 4203->3188 ADC4-Bit Err
MCM 05 4204->3189 ADC3-Bit Err
MCM 09 4211->3218 ADC-Bit width
MCM 10 4209->3190 ADC-Bit width |
|
154 | + | 158 | CERN | 2014-08-31 | |
155 | + | 159 | CERN | 2014-07-03 | Changed MCM after 6Weeks burnin\br
MCM 06 4254->3385 Temp. Diode \br
MCM 10 4260->3203 Dynamic P4err\br
MCM 01 4247->3242 Adc3 BitErr \br
| Changed MCM after 6Weeks burnin
MCM 06 4254->3385 Temp. Diode MCM 10 4260->3203 Dynamic P4err
MCM 01 4247->3242 Adc3 BitErr
|
|
156 | + | 160 | CERN | 2014-07-04 | |
157 | + | 236 | CERN 104 R-B21 | 2015-05-20 | changed MCM serNr 4799 in slot 13 with MCM serNr 2952. Problem: failures of the LUT slope method in the digital channel number 3. | Back from ZDC |
|
158 | + | 238 | ZDC - CERN | 2010-11-19 | |
159 | + | 252 | ZDC - CERN | 2010-11-19 | |
160 | + | 249 | CERN 104 R-B21 | 2015-05-20 | Cannot upload the debug file from the long-term LVDS tests. The file is too large.
VA | Back from ZDC |
|
161 | | 60 | KS LAB | 2009-09-18 | Canged all good MCMs for repair.
Powerup and then shutdown in KSLAB Crate. (5V to low)? |
|
162 | | 83 | KS-LAB | 2010-11-23 | MCM replacement:
Replaced MCM 2771 with MCM 2781 due to incomplete DB entries for the former MCM. The PPM was retested.
Victor Andrei
| Retested in HD OK. | back from CERN to repair KS |
|
163 | | 80 | KS-LAB | 2014-01-31 | MCM replacement:
MCMs 2676, 2678 and 2680 (positions 11, 12 and 14) were replaced with MCMs 2782, 2783 and 2784 due to incomplete DB entries for the former MCMs. The PPM was retested (single board tests).
Victor Andrei | back from CERN to repair KS |
|
164 | | 237 | KS-LAB | 2010-11-22 | |
165 | | 129 | KS-Lab | 2010-10-19 | Hardware:
replaced MCM 3 SerNr 3851 -> 3148
phos4 init error
replaced MCM 6 SerNr 3855 -> 3147
Analog Ch1 Bad ADC values
replaced MCM 10 SerNr 3863 -> 3149
Serial Interface Problems
replaced MCM 12 SerNr 3866 -> 3244
ASIC no Readout Data
CAN R4k7 implemented
| PPM is in KIP for Repair. MCM01-MCM11 exchanged. CAN-Brd changed to #168.
Population as of April 30th 2010 | Update Tests KS |
|
166 | | 145 | KS-Lab | 2017-02-24 | MCM 3385 changed to 3201 KS | PPM was in KIP for Repair. All MCMs exchanged. The new population as of
April 30th 2010 | Remove + | Remove + |
|
167 | | 255 | KIP ATLAS Lab | 2017-08-04 | Mounted nMCMs for eventual TREX tests |
|
168 | | 239 | KIP ATLAS Lab | 2017-08-04 | Mounted nMCMs for eventual TREX tests |
|
169 | | 241 | KIP ATLAS Lab | 2017-08-04 | Mounted nMCMs for eventual TREX tests |
|
170 | | 245 | ZDC - CERN | 2015-06-02 | Equipped with nMCMs for transport to CERN for ZDC. | Added AnIns to Database |
|
171 | | 240 | KIP ATLAS Lab | 2017-08-04 | Mounted nMCMs for eventual TREX tests |
|
172 | | 254 | KIP ATLAS Lab | 2010-11-19 | |
173 | | 250 | KIP ATLAS Lab | 2017-08-04 | Mounted nMCMs for eventual TREX tests |
|
174 | | 253 | ZDC - CERN | 2015-06-02 | Equipped with nMCMS for transport to CERN fot ZDC. | Added AnIns to Database |
|
175 | | 246 | KIP ATLAS Lab | 2017-08-04 | Mounted nMCMs for eventual TREX tests |
|
176 | | 247 | ZDC - CERN | 2015-06-02 | Equipped with nMCMs for transport to CERN for ZDC. | Added AnIns to Database |
|
177 | | 248 | ZDC - CERN | 2015-06-02 | Equipped with nMCMs for transport to CERN for ZDC. | Added AnIns to Database |
|
178 | | 251 | KIP ATLAS Lab | 2017-08-04 | Mounted nMCMs for eventual TREX tests |
|
179 | | 243 | KIP ATLAS Lab | 2017-08-04 | Mounted nMCMs for eventual TREX tests |
|